Feature

  • True Online Double-Conversion Technology
  • DSP Technology Guarantees High Performance
  • Pure Sine Wave Output
  • IGBT Based both Rectifier & Inverter
  • Compact Footprints
  • Input Power Factor Correction ≥0.99
  • Output Power Factor unity (1.0, kVA=kW)
  • User Friendly LCD for Monitoring
  • Supports Frequency Conversion Mode
  • ECO mode operation for energy saving
  • Emergency power off function (EPO)
  • Fan Speed Regulation as per Load
  • Automatic Static Bypass Switch
  • Lithium-ion Battery Technology
  • 10-Years Design Life
  • Smart Monitoring via SNMP / IoT (opt)
  • Cold Start & Soft Start Features
  • Auto Restart Function
  • Inbuilt Surge Protection
  • Generator Input Compatible
  • Best Suitable for Switch / Firewall / CCTV / Server
Model MFILVX02L1B50 MFILVX03L1B50 MFILVX05L1B100 MFILVX10L2B100 MFILVX15L3B100 MFILVX20L4B100 MFILVX25L5B100 MFILVX30L6B100
Capacity (kVA) 2 3 5 10 15 20 25 30
No. of UPS Modules 1 2 3 4 5 6
INPUT
Nominal Voltage 230V AC (1Ph+N+PE, 3 Wire) 230V AC (1Ph+N+PE, 3 Wire)/ 400V AC (3Ph+N+PE, 5 Wire)
Operating Voltage Range 110V~280V AC (P-N) Load Dependent
Operating Frequency
Range
50 / 60 Hz ± 10% (Auto Sensing)
Power Factor ≥ 0.99
OUTPUT
Output Voltage 230V AC 230V AC/ 400V AC
Voltage Regulation ± 1%
Power Factor Unity
Frequency (Battery Mode) 50/60 Hz ± 0.1Hz
Crest Factor 3:1
Harmonic Distortion
(THDv)
≤ 2%
Efficiency 94.0% Dual Conversion Mode, 99.0% ECO Mode
BATTERY
Max. Charging Current
(Configurable)
60A 120A 180A 240A 300A 360A
Battery Voltage 48V DC
Battery Chemistry LiFePO4
Maximum Discharge
Rate
1.0C
No. of Battery Modules 1 2 3 4 5 6
Battery Energy 2.4kWh 4.8kWh 9.6kWh 14.4kWh 19.2kWh 24kWh 28.8kWh
Expendable Battery Pack 10 5 4 3 2
Battery Backup Time 1~5 hours (depends on the connected load)
Recharge Time (Typical) 2 Hours (Approx.)
SYSTEM FEATURES
LCD Indications Input Voltage/Frequency, Output Voltage/Frequency, Battery Voltage, Load Watt/VA/%, Operation Mode such as "On Line", "On Batt" or "On Bypass", Fault Codes,
Battery & Load Bar graph
LED Indications Normal Operation, Bypass, Abnormal, Fault and Battery Mode
Alarm / Protection Batt. Low, DC High, Inverter Under/Over Voltage, UPS Overload, Short Circuit, Fan Failure and UPS Fault
Transfer Time AC to Battery: Zero, Inverter to Bypass: 4ms (Typical)
Overload Capability 105-150% for 10s, >150% for 5s
Degree of Protection IP20
ENVIRONMENT
Temperature Operating 0~50°C (No-Derating)
Storage -15°C~ 60°C
Humidity 0~95% RH Non-condensing
Altitude <1500M
Noise <55dBA
COMMUNICATION INTERFACE
Standard RS-232/ USB/ EPO
Optional SNMP/Dry Contact/ModBus/IoT
Monitoring Software BPE Cyber/ UPSilon 2000
STANDARDS
Quality ISO 9001, ISO 14001, ISO 27001, ISO 45001, ISO 50001, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE

Feature

  • True Online Double-Conversion Technology
  • DSP Technology Guarantees High Performance
  • Pure Sine Wave Output
  • IGBT Based both Rectifier & Inverter
  • Compact Footprints
  • Input Power Factor Correction ≥0.99
  • Output Power Factor unity (1.0, kVA=kW)
  • User Friendly LCD for Monitoring
  • Supports Frequency Conversion Mode
  • ECO mode operation for energy saving
  • Emergency power off function (EPO)
  • Fan Speed Regulation as per Load
  • Automatic Static Bypass Switch
  • Lithium-ion Battery Technology
  • 10-Years Design Life
  • Smart Monitoring via SNMP / IoT (opt)
  • Cold Start & Soft Start Features
  • Auto Restart Function
  • Inbuilt Surge Protection
  • Generator Input Compatible
  • Best Suitable for Switch / Firewall / CCTV / Server
Model MFILVX02L1B50 MFILVX03L1B50 MFILVX05L1B100 MFILVX10L2B100 MFILVX15L3B100 MFILVX20L4B100 MFILVX25L5B100 MFILVX30L6B100
Capacity (kVA) 2 3 5 10 15 20 25 30
No. of UPS Modules 1 2 3 4 5 6
INPUT
Nominal Voltage 230V AC (1Ph+N+PE, 3 Wire) 230V AC (1Ph+N+PE, 3 Wire)/ 400V AC (3Ph+N+PE, 5 Wire)
Operating Voltage Range 110V~280V AC (P-N) Load Dependent
Operating Frequency
Range
50 / 60 Hz ± 10% (Auto Sensing)
Power Factor ≥ 0.99
OUTPUT
Output Voltage 230V AC 230V AC/ 400V AC
Voltage Regulation ± 1%
Power Factor Unity
Frequency (Battery Mode) 50/60 Hz ± 0.1Hz
Crest Factor 3:1
Harmonic Distortion
(THDv)
≤ 2%
Efficiency 94.0% Dual Conversion Mode, 99.0% ECO Mode
BATTERY
Max. Charging Current
(Configurable)
60A 120A 180A 240A 300A 360A
Battery Voltage 48V DC
Battery Chemistry LiFePO4
Maximum Discharge
Rate
1.0C
No. of Battery Modules 1 2 3 4 5 6
Battery Energy 2.4kWh 4.8kWh 9.6kWh 14.4kWh 19.2kWh 24kWh 28.8kWh
Expendable Battery Pack 10 5 4 3 2
Battery Backup Time 1~5 hours (depends on the connected load)
Recharge Time (Typical) 2 Hours (Approx.)
SYSTEM FEATURES
LCD Indications Input Voltage/Frequency, Output Voltage/Frequency, Battery Voltage, Load Watt/VA/%, Operation Mode such as "On Line", "On Batt" or "On Bypass", Fault Codes,
Battery & Load Bar graph
LED Indications Normal Operation, Bypass, Abnormal, Fault and Battery Mode
Alarm / Protection Batt. Low, DC High, Inverter Under/Over Voltage, UPS Overload, Short Circuit, Fan Failure and UPS Fault
Transfer Time AC to Battery: Zero, Inverter to Bypass: 4ms (Typical)
Overload Capability 105-150% for 10s, >150% for 5s
Degree of Protection IP20
ENVIRONMENT
Temperature Operating 0~50°C (No-Derating)
Storage -15°C~ 60°C
Humidity 0~95% RH Non-condensing
Altitude <1500M
Noise <55dBA
COMMUNICATION INTERFACE
Standard RS-232/ USB/ EPO
Optional SNMP/Dry Contact/ModBus/IoT
Monitoring Software BPE Cyber/ UPSilon 2000
STANDARDS
Quality ISO 9001, ISO 14001, ISO 27001, ISO 45001, ISO 50001, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE