MFP Series 10~20kVA

A high-performance True Online Double Conversion UPS with DSP control and pure sine wave output. It uses IGBT-based inverter and rectifier for high efficiency and reliability. Features include ≤1% input current harmonics, 0.99 input power factor, and 1.0 output power factor. It supports 16–20 batteries, wide input voltage (208–480V) and frequency ranges, generator compatibility, and phase reversal protection.

Submit Your Enquiry & Our Experts Will Assist You

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Features:
  • True Online Double Conversion with DSP Controlled Pure Sine Wave Design
  • Input Current Harmonic: ≤ 1%
  • Optimization Battery Group, The Quantity of Battery: 16/18/20 Nos.
  • High Input Power Factor 0.99
  • High Output Power Factor 1.0
  • Wide Input Voltage Range: 208~480V AC
  • Wide Input Frequency Range (50Hz: 45~55Hz / 60Hz:54~66Hz)
  • Generator Compatibility & Phase Reversal Protection
  • Support Economic Operation (ECO) Mode
  • Self-Testing while UPS Startup
  • Optional Parallel up to 4 units
  • Static Bypass and Cold Start
  • Auto Start and cold start function


Rear Panel
1. Fan
2. Input Switch
3. Output Switch
4. Maintenance Switch
5. Terminal
6. Com Port
7. USB Port
8. Parallel Port
9. EPO
10. Intelligent Slot / SNMP(Optional)

MODEL MFP3110L16 MFP3120L16
Capacity 10 kVA 20 kVA
INPUT
Nominal Voltage 380V / 400V / 415V AC (3P+N+PE)
Operating Voltage Range 190V~499V AC Load Dependant
Operating Frequency Range 50 / 60 Hz ± 10% (Auto Sensing)
Power Factor ≥0.99
Bypass Voltage - 40% ~ +15% (Configurable)
Frequency ± 5% (Configurable)
ECO Range Same as the Bypass, can be configured
Generator Input Compatible
OUTPUT
Rated Voltage 220V / 230V / 240V AC L+N+PE (Configurable)
Power Factor 0.8 (Standard) 0.9 / 1.0 (Optional)
Voltage Regulation ±1%
Frequency Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.5 Hz Battery Mode
Crest Factor 3:1
Overload ≤105% for Continuous, ≤ 125% for 10 Min, ≤ 150% for 60 Sec, ≥ 150% for 200ms
Harmonic Distortion (THDv) ≤ 1%
Efficiency 94.0% Dual Conversion Mode, 99.0% ECO Mode
BATTERY
Battery Voltage 192V DC / 216V & 240V DC (Configurable)
Typical Recharge Time 4-5 Hours to 90% of full Capacity
Charge Current 10A Configurable (optional)
SYSTEM FEATURES
IP Protection IP20
Transfer Time Zero
EPO / ECO / CVCF Shutdown UPS Immediately / ECO and CVCF Mode can be Configurable
Alarm / Protection Short Circuit, Input Under/Over Voltage, Over Temperature, Over Current,
Over Load, DC BUS Under / Over Voltage and Battery low
LED Display Line Mode, Backup Mode, ECO Mode, Bypass Mode, Battery Low, Overload & UPS Fault
LCD Display Input Voltage, Input Frequency, Output Voltage, Frequency, Current; Load Percentage, Battery Voltage, Charging/
Discharging,Current Temperature & Remaining Battery Backup Time, Load VA/W, Load and Battery Bargraph
ENVIRONMENTAL
Temperature Operating: 0~50°C*, Storage: -15°C ~ 60°C
Humidity / Altitude 0~95% RH Non-condensing / <1500 M
Noise <50dBA
PHYSICAL
Dimension WxDxH (mm) 191 x 495 x 350 191 x 495 x 515; Customized as optional
Net Weight (Kg) 18.5 26.5
STANDARDS
Quality ISO 90001, ISO 14001, ISO 27001, ISO 45001, ISO 50001, BIS, RoHS, FCC
Safety IEC/EN62040-1; Conformity to IEC / EN
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE, Compliance to UL
COMMUNICATION INTERFACE
Standard RS-232
Optional SNMP / ModBus / Dry Contact / USB / RS-485
Monitoring Software NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000