Features:
  • High frequency and double conversion with PWM technology
  • Fully digitized microprocessor control
  • Wide input range
  • LCD display
  • Cold start
  • Advanced battery management
  • Automatic battery charging in UPS off mode
  • Lightning and surge protection
  • Short circuit and overload protection
  • Fan speed adjusted by load automatically
  • Network/fax/modem surge protection
  • Optional extension battery pack
  • EMI/RFI noise filter
  • Smart Rs232 communication with monitoring software
  • Optional SNMP card slot
  • EPO function (optional)
  • Input L and N reversed alarm function
  • Size 2U & 3U
  • IGBT based charger for smart battery management & improve input powerfactor
Overview:
  • 1. RS232
  • 2. USB
  • 3. SNMP Slot
  • 4. Fan
  • 5. External Battery Socket
  • 6. Output Socket
  • 7. Input Socket
  • 8. Circuit Breaker

MODEL MP1101L3 MP1101B3 MP1102L6 MP1102B6 MP1103L6 MP1103B6
Capacity (VA) 1000 2000 3000
INPUT
Nominal Voltage 230V AC (1Ph+N+PE)
Operating Voltage Range 100-280V AC at 50% Load; 160-280V AC at 100% Load
Operating Frequency Range 40-70 Hz (Auto Sensing)
Power Factor 0.99
Phase Single Phase In / Single Phase Out
OUTPUT
Output Voltage 200 / 208 / 230 / 240V AC ±1%
Output Frequency Mains Mode: 50/60 Hz ±3Hz (Sync to Mains); Battery mode: 50/60 Hz ±0.1Hz
Crest Factor / Power Factor 3:1 / 0.9
Harmonic Distortion (THDv) ≤ 1%
Efficiency 92%
Transfer
Time
AC to DC Zero
Inverter to Bypass 4 ms (Typical)
Waveform Pure Sinewave
BATTERY
DC Voltage 36V 72V
Charging Current 1A 6A 1A 6A 1A 6A
Battery Configure 03 x 7AH 06 x 7AH 06 x 9AH
Typical Recharge Time 8 Hrs. (to 90% of full Capacity)
SYSTEM FEATURES
LCD Indication Input Voltage & Frequency, Output Voltage & Frequency, Battery Voltage & Percent, Load Watt, VA & Percent,
Inverter Temperature, Operation Mode Such as “ONLINE”, “BYPASS”, “ONBATT”, “ERROR CODE”.
LED Indication Normal Operation, Bypass and Fault Indication
Audible Alarm Battery Mode, Low Battery, Over Load and Fault
Overload Capacity >130-150% for 30 Sec, >150% for 300 ms
Communication Interface RS-232, USB & SNMP (Optional)
ENVIRONMENTAL
Operating Temperature 0-50°C*
Storage Temperature -15-60°C
Humidity Range 0-95% (Non-Condensing)
Altitude 0-3000 m
Noise Level <50 dBA @ 1 mtr.
PHYSICAL
Net/Shipping Weight (Kg) 8/10 15.5/17.5 8.3/10.3 25/28 10/12 30/33
Dimension WxDxH (mm) 483x400x89 (2U) 438x580x133 (3U)
STANDARDS
Quality ISO 9000, ISO 14001, OHSAS 18001, ISO 27001, BIS, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE
Communication Interface
Standard RS-232
Optional SNMP / ModBus / USB / RS-485