MF Series 1kVA

This UPS features True Online Double Conversion with PWM technology, delivering a fully digitized, microprocessor-controlled operation and a high-frequency pure sine wave output. It offers a wide input voltage range with an LCD display for real-time monitoring and ensures superior efficiency with a high input power factor (>0.99). Equipped with IGBT-based inverter and rectifier, static and manual bypass, advanced battery management, and automatic battery charging even in off mode, the system guarantees reliable and uninterrupted power.

Submit Your Enquiry & Our Experts Will Assist You

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Features:
  • True Online Double Conversion with PWM technology
  • Fully digitized microprocessor-based control
  • High-frequency pure sine wave output
  • LCD display with wide input voltage range
  • High input power factor (>0.99)
  • IGBT-based inverter and rectifier
  • Static bypass and manual bypass facility
  • Isolation transformer compatible design
  • Advanced battery management system
  • Automatic battery charging in UPS OFF mode
  • EMI/RFI and noise filtering protection
  • Generator and solar compatible operation

MODEL MF1101L3
Capacity (VA) 1000
INPUT
Nominal Voltage 220V/230V/240V AC (1Ph+N+PE, 3 Wire)
Operating Voltage Range 100V~300V AC Load Dependent
Operating Frequency Range 50 / 60 Hz ± 10% (Auto Sensing)
Power Factor >0.99
OUTPUT
Output Voltage/Power Factor 220V / 230V / 240V AC / ±1% / 0.8 Std., 0.9 Optional
Output Frequency Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode
Harmonic Distortion (THDv) <1%
Crest Factor 3:1
Efficiency 94.0% Dual Conversion Mode, 99.0% ECO Mode
BATTERY
DC Voltage 96V
Battery Type & Number 12V/9AH × 08
Charge Current 1 A
Typical Recharge Time 4-5 Hours (90% of full capacity)
SYSTEM FEATURES
LCD Indication Input Voltage/Frequency, Output Voltage/Frequency, Battery Voltage, Load Watt/VA and %, Inverter Temperature, Operation Mode such as “On Line”, “On Batt” or On “Bypass”, Fault Codes, Battery & Load Bar graph
LED Indication Normal Operation, Bypass, Abnormal, Fault and Battery Mode
Alarms / Protection Batt. Low, DC High, Inverter Under/Over Voltage, UPS Over Load, Short Circuit, Fan Failure and UPS Fault.
Overload Capability ≤125% for 10 min, >125~150% for 1 min, >150% for 200 ms
Transfer Time AC to Battery : 0ms, Inverter to Bypass : 4ms (Typical)
ENVIRONMENTAL
Temperature Operating: 0~50°C*, Storage: -15°C ~ 60°C
Humidity / Altitude 0~95% RH Non-condensing / <1500m No derating
Noise ≤45dBA
PHYSICAL
Dimension WxDxH (mm) 192×469×399
Weight (Kg) 28.1
STANDARDS
Quality ISO 9001, ISO 14001, ISO 27001, ISO 45001, ISO 50001, BIS, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE
COMMUNICATION INTERFACE
Standard RS-232
Optional SNMP / ModBus / Dry Contact / USB / RS-485
Monitoring Software NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000