3 BP Series 650VA 2200VA

This UPS uses MOSFET PWM technology with a built-in AVR, EMI/RFI filter, and surge suppressor for stable operation. It supports cold start on battery, overload and battery drain protection, and includes a night charging mode. Powered by a reliable microprocessor, it offers plug-and-play setup, generator compatibility, and an optional USB card for auto shutdown software.

Submit Your Enquiry & Our Experts Will Assist You

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Features:
  • MOSFET PWM Technology
  • Built in AVR and EMI/RFI Filter
  • Surge Suppressor
  • Cold Start on Battery
  • Overload Protection
  • Battery Drain Protection
  • Built in Night Charging Mode
  • Powerful Microprocessor
  • Optional USB Card for Auto Shutdown
  • Software
  • Plug and play
  • Generator Compatible

MODEL BP650V BP1000 BP1200 UPS1000V BP1500 BP2200
INPUT
Capacity (VA) 600 1000 1500 2000
Voltage (VAC) 120~300VAC
Frequency (Hz) 50 / 60Hz ± 10Hz Auto Sensing
OUTPUT
Voltage AVR Mode 200~245V
Voltage Battery Mode 230VAC ±10%
Frequency (Hz) on Battery Mode 50/60Hz ± 0.1Hz
Waveform Simulated Sine Wave
Transfer Time (ms) 4-8 ms Typical
BATTERY
Voltage 12V DC 24V DC
Internal Battery Standard 1x12V/7AH 1x12V/9AH 2x12V/7AH 4x12V/7AH External, 10A
Charger Connect
upto 100 Ah Battery
Optional 1x12V/12AH 2x12V/12/9/7AH 2x12V/9AH 4x12V/9AH
Type Sealed Maintenance Free Lead Acid VRLA
Recharge Time 6-8 Hours to 90% After Complete Discharge
BACKUP CHART
No. of PC Support
(Recommended)
01 Nos. 02 Nos. 02 Nos. 04 Nos. 6-7 Nos.
On 1PC Load Standard Model
(Depends on PC Configuration)
16-25 Min. 45-50 Min. 60-65 Min. >2 Hrs.
SYSTEM FEATURES
Audible Alarms Low Battery, Overload, Short Circuit and Fault Conditions
LED Display AC Mode : Green Lighting, Battery Backup Mode : Orange Lighting, Fault Mode : Red Lighting
Protection Battery Low, Overload, Short Circuit, AC Input Low/ High & Fault conditions
Degree of Protection IP21
Cold Start Yes
Type of Enclosure ABS
PHYSICAL
Dimensions (WxDxH) mm 99x280x143 145x400x160 147x351x163 170x410x170 395x145x220
Net Weight Standard Model (Kg) 4.16 6.5 7.96 10 13.5
Nos. of Power Outlet 3 4 (1 Printer+3 Battery) 3 4
STANDARD
Quality ISO 9000, ISO 14001, OHSAS 18001, ISO 27001, BIS and RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2, IEC/EN62040-3, Complying to CE
ENVIRONMENT
Temperature Operating: 0~50°C*, Storage: -10°C ~ 55°C
Humidity / Altitude 0~95% RH Non-condensing / <1500 M
Noise Low Audible Noise Level
COMMUNICATION
Communication Port RS-232 / USB (Optional)
Monitoring Software (Optional) View Power/ UPSilon 2000 (Optional)